Special Features. 1 HPc. Power Plus 140 Volt DC motor provides power to operate almost any residential garage door. Maximum opening speed of 12.0 inches per second † to provide the ultimate in fast performance.
Delivers maximum lifting force and greater reliability. Integrated motion detector provides convenience and security to the two 100 Watt bulb lighting system.
How to Troubleshoot the Powermax Security System. Problems with the Visonic PowerMax usually fall into one of three areas: sensor trouble, transmitter trouble or system trouble. Conveniently, the Visonic PowerMax security systems have a trouble indicator. 'TRBL' will flash on the display, the trouble indicator will light up and the control box will. The Stop and/or Reset (if provided separately) must be located in the line-of-sight. Solar Power Max. Check the national and local building codes BEFORE installation. The operator type will display as 'LA'.
SmartSet ™ programming: Push button programming makes set up fast and easy. Auto Seek Dual Frequency: System will automatically seek either the 315 or 390 MHz frequency produced by a remote, helping to ensure the opener will respond regardless of nearby frequency interference. GenieSense ™ Monitoring and Diagnostic Technology: Delivers the power needed at every movement of the garage door and continuously monitors the operation of the door, stopping operation when significant changes occur. GenieSense™ minimizes noise, wear and tear on the door, and improves overall safety. Puts an invisible beam across the door opening.
The door stops and reverses to open position if anything passes through the beam. Provides safety by continuously monitoring operation of the door, stopping the operation to alert you when significant changes occur. Superior encryption technology (also known as rolling codes) that prevents piracy of the radio signal that opens your garage door by continually seeking a new code from billions of combinations. Works with ALL HomeLink and Car2U systems regardless of when those systems were made. No additional external repeater box or compatibility bridge needed.
Dlee1959 June 14, 2017 Great customer care assistance. Great customer care assistance. Received an iPhone tutorial yesterday from a representative in Dallas for over an hour that was excellent and enabled installation of a replacement wireless keypad for my Genie garage door opener. She had the patience of a saint and enabled the restoration of my garage door that was defunct after I tried to reset the code on the new keypad.
She deserves recognition as a customer care representative. Genie Company - 5 out of 5 stars / Dlee1959. Dennis1964 July 11, 2016 I am so sorry I didn't buy (a Genie opener) the first time! This Genie is an awesome product!!! 14 Months ago I bought a Extreme Door opener from Menards 3/4 horse and it is just out of the one year warranty and it completely stopped working like the electronic just stopped. It cost me $168 $50 less than the Genie but I didn't have the money so I bought the cheaper one.
![]()
DON'T BUY THE CHEAPER ONE. It was a total waste of my time and money, I learned to never cheap out on a garage door opener. This time I bought the Genie PowerMax 1500 it is 1 horse insted of 3/4 horse and it comes with a 'LIFETIME' warranty plus it is a Screw drive (very quiet) and it is very high quality! I am so sorry I didn't buy it the first time! Please learn from my mistake.
This Genie is an awesome product!!! GenieCompany.com - 5 out of 5 stars / Dennis1964.
Visonic PowerMax / PowerMaster. Table of contents. Description Visonic produces the PowerMax and PowerMaster alarm panel series. The PowerMax or PowerMaster provide support for a serial interface that normally is used for programming and the PowerLink functionality. DomotiGa uses this serial interface to communicate to the alarm panel. The serial interface is not installed by default, but can be ordered from a Visonic vendor for about 30-50 euro (product is normally named 'Visonic RS-232 Adaptor Kit', an USB kit is also available).
Visonic doesn't provide a specification of the serial protocol, but it has been reverse engineered, which DomotiGa uses. Supported Alarm panels Alarm Panel Type PowerMax PowerMax+ PowerMax Express PowerMax Pro PowerMax Pro Partition PowerMax Complete PowerMaster 10 G2 PowerMaster 30 G2 Installation The installation of the serial interface is described in the Visonic manuals. After the interface has been properly build-in, connect the serial cable to DomotiGa. It is possible you require a RS-232 to USB converter, best to use the ones based on the FTDI chip. Configuration DomotiGa will normally auto-create the Visonic magnet and motion sensors for you.
The PowerMaster motion sensors (PIR) can only trigger 1 motion event every 30 seconds, due to limitations in the protocol. Direct Connection: PowerMax+ It is recommend to use the serial interface from Visonic, but it is also possible to directly connect a TTL to USB connector to the Visonic panel. The TTL to USB has to be 3.3V. Locate the 10 pin connector, labeled PC/IP and connect it as follows: Pin Description Pin Description Pin Description Pin Description 1 TX 2 3 RX 4 5 GND 6 GND 7 8 9 10 11 12 13 14 Connect your TTL TX to the RX, and the TTL RX to the TX PLEASE NOTE THAT THIS MAY DAMAGE YOUR PANEL I'M NOT RESPONSIBLE FOR ANY DAMAGE CAUSED, USE AT YOUR OWN RISK Direct Connection: PowerMax Pro and PowerMaster It is recommend to use the serial interface from Visonic, but it is also possible to directly connect a TTL to USB connector to the Visonic panel.
The TTL to USB has to be 3.3V. Locate the 10 pin connector, labeled PC/IP and connect it as follows: Pin Description Pin Description Pin Description Pin Description 1 2 3 RX 4 GND 5 TX 6 7 GND 8 9 10 Connect your TTL TX to the RX, and the TTL RX to the TX PLEASE NOTE THAT THIS MAY DAMAGE YOUR PANEL I'M NOT RESPONSIBLE FOR ANY DAMAGE CAUSED, USE AT YOUR OWN RISK Enrollment DomotiGa needs to enroll the PowerMax/Master to retrieve information from the panel, the 'download' code is during this process.
When the panel is enrolled properly it also can be used to arm/disarm and use the bypass command. If your panel doesn't support enrollment, e.g. It is very old, you can use the 'Force Standard Mode' to disable enrollment of the panel.
The panel is still useable for the sensors, but you need to manually create the sensors in DomotiGa. PowerMax+ The enrollment process can be done via the installer menu. When DomotiGa is started, go to the installer menu and use the 'Install PowerLink' option. When the enrollment process is completed successfully, the panel will give a beep. When there is already a PowerLink registered, it needs to be uninstalled first, before you try to connect DomotiGa as a new PowerLink module.
You can uninstall by selecting 'Install PowerLink' from the installer menu then pressing the disarm button. PowerMax Pro Some (newer) PowerMax Pro panels support automatic enrollment.
Best is to try if it does automatic enrollment otherwise follow the procedure of the PowerMax+. PowerMax Express Supports automatic enrollment. During the initial enrollment the panel will send an 'access denied' and we can send a new download code.
PowerMax Complete Supports automatic enrollment. During the initial enrollment the panel will send an 'access denied' and we can send a new download code. PowerMaster 30 Supports automatic enrollment.
During the initial enrollment the panel will send an 'access denied' and we can send a new download code. Question & Answers Q: The Visonic starts beeping shortly after DomotiGa is stopped? A: The alarm panel sends keep-alive across the serial interface and if these are not acknowledged, the panel will see this as a fault. Start DomotiGa again and the connection will be re-established and the beeping should stop (and the panel will go in normal operating mode again) Q: The Visonic starts beeping shortly after DomotiGa is stopped? A: With a PowerMaster you can disable the beeping when the connection is interupted. Use the Visonic Remote Programmer for this.
For the PowerMax you need to initialize the connection again, by restarting DomotiGa. Q: I want to remove the connection, but the Visonic continues to give a fault? A: For the PowerMaster it is required to remove the power and battery to reset the fault state to normal Resources. Updated by:, Updated ago Access count: 39860 since 2015-01-17 Attached Files Files (4).